M-Series® Mag MeterModels M2000 and M5000Field Verication DeviceUser GuideIOM-833-01 (8-11)IMPORTANT: This manual contains important information.REA
Page 10 8-11Field Verication DeviceM5000Opening the Cover1. Using a ¼ inch slotted screwdriver, remove the two top screws from the front
Page 118-11User GuideM5000 Harness Connections1. Clip the alligator clip labeled Detector Ground to either of the hex nuts mounted on top of the mete
Page 12 8-11Field Verication DeviceDisplay and KeypadDisplayThe display is a backlit LCD and displays the current date and time, percent o
Page 138-11User GuideMenu StructureRefer to the following chart when navigating the Verification Device menus.
Page 14 8-11Field Verication DeviceVerication Device SettingsPress the On/Off button on the Device and wait for the SelfTest to complete.
Page 158-11User GuideTime1. Select StartMenu > Settings > Misc > Time. 2. Edit the hour and minutes in the edit box by using the numeric ke
Page 16 8-11Field Verication DeviceVerication Device TestsMain TestThe main test is the standard process for meter testing. The result of
Page 178-11User Guide9. The testing is completed automatically in 10 steps. During the test the ow meter shows Testing in progress on the display.10
Page 18 8-11Field Verication DeviceAmplier Test • Detector Current• The current [A] and excitation frequency [Hz] are measured• Analog
Page 198-11User GuideMain Test FailsShows the test result of the last Main Test.Meter IdenticationThe menu displays information about the connected f
Field Verication DevicePage ii 8-11
Page 20 8-11Field Verication DeviceAboutInformation about the Verification Device• Serial number• Version• Compilation date• FlashOsCh
Page 218-11User GuidePC SoftwareInstallation of the PC SoftwareInsert the software CD, open setup.exe and follow the instructions. An icon on the Desk
Page 22 8-11Field Verication Device5. The downloaded measurements are displayed on the left side of the window.6. Select the new measur
Page 238-11User GuidePrint Reports1. Select the measurment which you want to print.2. Click File and Print.3. A preview window is shown:4. Clic
Export Reports1. Select Export all... for all or Export selected... for exporting one measurement.2. Save the data in “CSV” format to be imported t
CONTENTSDisclaimer ...
Verication Device Tests ... 16M
Page 58-11User GuideDisclaimerThe user/purchaser is expected to read and understand the information provided in this manual, follow any listed safety
Page 6 8-11Field Verication DeviceField Verication Device FunctionsThe Device also: • Determines if the M-Series meter is within one per
Page 78-11User GuideCable ConnectionsCable HarnessThe cable harnesses are tagged with either M2000 or M5000 on the outer harness wire cover so the use
Page 8 8-11Field Verication DeviceM2000Disconnect the power to the amplifier before connecting the cable harness of the Verification Devic
Page 98-11User GuideM2000 Harness Connections1. Clip the alligator clip labeled Detector Ground to either of the hex nuts mounted on top of the meter
Commentaires sur ces manuels