Badger-meter B3000 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour l'eau Badger-meter B3000. Badger Meter B3000 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Compact Digital Flow Monitor
Model B3000
DSY-PM-00022-EN-03 (March 2014)
Programming Manual
2
1
J1
S1
Menu
S4
Enter
S3
Up
S2
Down
COM
1
2
12
1
C
L
A
S
S
I
F
I
E
D
SERIAL
MODEL
USC
E113407
Electrical and
Hazardous
Location Safety
!
Class I Div 1 Groups C,D
Class I Zone 0, IIB, T4
Class II Div 1 Groups E,F,G
Class III
-30∞C<Tamb<70∞C
WARNING:
CAUTION:
ADVERTSSEMENT:
FAITES ATTENTION:
Substitution of Components May Impair Intrinsic
Safety Use Only Blancett B300028, 3.6V Lithium
Battery. La Substitution De Composants Peut
Compromettre La Securtie Intrinseque
Utiliser Suelement Que Des Batterie Blancett B300028, 3.6V Lithium
Intrinsically Safe When
Installed Per Drawing -
B300020
SÈcuritÈ intrinsËque
lorsqu'il est installÈ
par le dessin B300020
4-20mA Loop Pulse Output Reset Input RS485 Turbine Input
V Max 28 Vdc 28 Vdc 5 Vdc 10 Vdc Voc=3.5V
I Max 26mA 100mA 5mA 60mA Ics=3.6mA
Ci 0.5µF 0.0µF 0.0µF 0.0µF Ca=1.5µF
Li 0.0mH 0.0mH 0.0mH 0.0mH La=1.65H
SERIAL
MODEL
E113407
Electrical and Hazardous
Location Safety
!
Class I Div 1 Groups C,D
Class I Zone 0, IIB, T4
Class II Div 1 Groups E,F,G
Class III
-30∞C <Tamb<70∞C
WARNING:
ADVERTSSEMENT:
Substitution of Components May Impair Intrinsic
Safety
La Substitution De Composants Peut
Compromettre La Securtie Intrinseque
Intrinsically Safe When
Installed Per Drawing -
B300020
SÈcuritÈ intrinsËque
lorsqu'il est installÈ
par le dessin B300020
Pulse Output Reset Input Turbine Input
V Max 28 Vdc 5 Vdc Voc=2.5V
I Max 100mA 5mA Ics=1.8mA
Ci 0.0µF 0.0µF Ca=1.5µF
Li 0.0mH 0.0mH La=1.65H
USC
XXXXXXXXXX
XXXXXXXXXX
!
USC
Electrical and
Hazardous
Location Safety
E113407
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - Programming Manual

Compact Digital Flow MonitorModel B3000 DSY-PM-00022-EN-03 (March 2014)Programming Manual21J1S1MenuS4EnterS3UpS2DownCOM12121CLASSIFIEDSERIALMODELUSCE1

Page 2 - Page ii March 2014

Compact Digital Flow Monitor, Model B3000 Page 10 March 2014INSTALLATIONConnecting the B3000 to a Frequency Output DeviceMost turbine flow sensors pr

Page 3 - CONTENTS

Programming ManualPage 11 March 2014JP1JP2JP3Input Total Pulse SignalP1Freq. In4-20mAIso Total PluseTR_BTR_ARS485 GndSetpoint 1Setpoint 2Gnd+–+–+–Tota

Page 4

Compact Digital Flow Monitor, Model B3000 Page 12 March 2014POWER CONNECTIONSStandardThe power supply used in the B30A/B/X/Z is an internal lithium 3

Page 5 - Page v March 2014

Programming ManualPage 13 March 2014SolarA solar cell mounted on the top of the monitor in the B30S charges an internal 3.6V DC nickel-cadmium battery

Page 6 - INTRODUCTION

Compact Digital Flow Monitor, Model B3000 Page 14 March 2014OPERATING THE MONITORThe monitor has three modes of operation referred to as the Run, Pro

Page 7 - SPECIFICATIONS

Programming ManualPage 15 March 2014ButtonsMENU – Switches between normal running and programming modes.UP Arrow (▲) – In programming mode scrolls for

Page 8

Compact Digital Flow Monitor, Model B3000 Page 16 March 2014Programming Using Frequency Output Turbine Flow MetersEach Blancett turbine flow meter is

Page 9 - PART NUMBER CONSTRUCTION

Programming ManualPage 17 March 2014PROGRAMMING PARAMETERSConventionsThe individual programming parameters are arranged as follows.Top Line – Indicate

Page 10 - INSTALLATION

Compact Digital Flow Monitor, Model B3000 Page 18 March 201421Roll-OverIndicatorTotalizerModeTotalRoll-OversFigure 17: Grand totalTest TestThe Test

Page 11 - (see Figure 7 and Figure 8)

Programming ManualPage 19 March 2014Select Rate Units Setup Rate SUExtended FunctionThe Rate SU is only available on the standard and solar liquid mon

Page 12 - POWER CONNECTIONS

Flow Monitor, B3000 Flow Monitor For Gas or Liquid MetersPage ii March 2014

Page 13 - Solar Cell

Compact Digital Flow Monitor, Model B3000 Page 20 March 2014ENTER SPECIFIC GRAVITY VALUE (SPEC GR)Basic Function (activated when mass units are selec

Page 14 - Figure 14: Keypad detail

Programming ManualPage 21 March 2014GAS COMPENSATIONGas Turbines OnlyFluid measured by the gas turbine meter is compressible, and is also affected by

Page 15

Compact Digital Flow Monitor, Model B3000 Page 22 March 2014Totalizer Pulse Output PulsOutBasic FunctionThe PulsOut parameter can be either enabled o

Page 16

Programming ManualPage 23 March 2014Flow at 20 mA Fl=20mABasic FunctionWhen the display is operated using loop power, the flow rate that corresponds t

Page 17 - PROGRAMMING PARAMETERS

Compact Digital Flow Monitor, Model B3000 Page 24 March 2014Linearization LinearExtended FunctionEnhanced accuracy can be obtained by linearization o

Page 18 - Figure 18: Test mode screen

Programming ManualPage 25 March 2014Unit Under Test (UUT) Calibration Data Table In GPMActualGPMUUT Frequency UUT Actual K factor(Hz x 60) Nominal KLi

Page 19

Compact Digital Flow Monitor, Model B3000 Page 26 March 2014Set Point 1 SetPt 1Extended FunctionThe set point is the flow value at which the output t

Page 20

Programming ManualPage 27 March 2014MinimumFlowMaximumFlowOutput ONOFF Setpoint ON SetpointHysteresis Output OFFFigure 26: Set point actionsOTE:N Nei

Page 21 - GAS COMPENSATION

Compact Digital Flow Monitor, Model B3000 Page 28 March 2014Clear Grand Total CLR G-TBasic FunctionAt the Clr G-T prompt, press ENTER. The display wi

Page 22 - Internal

Programming ManualPage 29 March 2014APPENDIXTROUBLESHOOTING GUIDETrouble RemedyNo LCD DisplayBattery – B30A/B/X/Z only Check battery voltage. Should b

Page 23 - FAST MAX MIN AVG

Programming ManualPage iii March 2014CONTENTSINTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24 - Nominal K Factor

Compact Digital Flow Monitor, Model B3000 Page 30 March 2014Battery Replacement (B30A/B/X/Z only)Battery powered monitors use a single 3.6V DC “D” si

Page 25 - Set Points

Programming ManualPage 31 March 20145. Cut the tie wrap holding the battery to the mounting plate and remove the worn-out battery.6. Install a new t

Page 26

Compact Digital Flow Monitor, Model B3000 Page 32 March 2014MENU MAPSADVANCED I/O LIQUIDModbusModbusBasicExtendedSub MenuPress and hold MENU buttonfo

Page 27 - Figure 27: Set point example

Programming ManualPage 33 March 2014FlowFlow-GT TestDisplayDisplay OptionsLIQUIDFlo UnitRate/Total UnitsGallons/Min GallonsOil Barrel/Day BarrelsMeter

Page 28 - Pushbutton

Compact Digital Flow Monitor, Model B3000 Page 34 March 2014Menu item only appears when Mass units are selected. LIQUID (Solar Powered)BasicExtended

Page 29 - Table 5: Gas K factors

Programming ManualPage 35 March 2014 GASBasicExtendedSub MenuPress and hold MENU buttonfor Extended settingsSTARTDayHourMinuteSecondRateIntRate Interv

Page 30 - Explosion Proof Enclosure

Compact Digital Flow Monitor, Model B3000 Page 36 March 2014ADVANCED I/O GASBasicExtendedSub MenuPress and hold MENU buttonfor Extended settingsDayHo

Page 31 - Release Tab

Programming ManualPage 37 March 2014GAS (Solar Powered)BasicExtendedSub MenuPress and hold MENU buttonfor Extended settingsSTARTDayHourMinuteSecondRat

Page 32 - ADVANCED I/O LIQUID

Compact Digital Flow Monitor, Model B3000 Page 38 March 2014K FACTORS EXPLAINEDThe K factor (with regards to flow) is the number of pulses that must

Page 33 - Press and hold MENU button

Programming ManualPage 39 March 2014 Example 3Known values are: Velocity = 4.3 ft/sec Inside Diameter of Pipe = 3.068 in.Find the area of the pi

Page 34 - LIQUID (Solar Powered)

Flow Monitor, B3000 Flow Monitor For Gas or Liquid MetersPage iv March 2014MODBUS INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35

Compact Digital Flow Monitor, Model B3000 Page 40 March 2014Badger Meter®Declaration of ConformityWe: Badger Meter, Inc.of: 4545 W. Brow

Page 36 - ADVANCED I/O GAS

Programming ManualPage 41 March 2014SYMBOL EXPLANATIONSCAUTIONREFER TO ACCOMPANYING DOCUMENTS.WARNINGEXPLOSION HAZARD  SUBSTITUTION OF COMPONENTS MAY

Page 37 - GAS (Solar Powered)

Compact Digital Flow Monitor, Model B3000 Page 42 March 2014EXPLOSIONPROOF ENCLOSUREThe ExDirect instrument enclosure is designed to house instrumen

Page 38 - K FACTORS EXPLAINED

Programming ManualPage 43 March 2014WARNINGTHE HAZARDOUS LOCATION INFORMATION SPECIFYING CLASS AND GROUP LISTING OF EACH INSTRUMENT ENCLOSURE IS MARKE

Page 39 - 423.9 pulses per gallon= =

Compact Digital Flow Monitor, Model B3000 Page 44 March 2014ABCDEFGHTHIS DRAWING IS PROPRIETARY TO BADGER METER INC. RECEIPT OR POSSESSION CONFERS N

Page 40 - Declaration of Conformity

Programming ManualPage 45 March 2014MODBUS INTERFACEA subset of the standard Modbus commands is implemented to provide access into the data and status

Page 41 - AVERTISSMENT

Compact Digital Flow Monitor, Model B3000 Page 46 March 2014Register MappingsData Component Name MODBUS RegistersAvailable UnitsLong Integer FormatSi

Page 42 - EXPLOSIONPROOF ENCLOSURE

Programming ManualPage 47 March 2014Modbus Coil Description Modbus Coil NotesReset Running Totalizer 1Forcing this coil ON will reset the running tota

Page 43

Compact Digital Flow Monitor, Model B3000 Page 48 March 2014C Source CodeA.1.1 CRC-16 Calculationsunsigned short crc_table[256] = {0x0000, 0xC0C1, 0

Page 44 - Page 44 March 2014

Programming ManualPage 49 March 2014WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE DIRECTIVEIn the European Union, this label indicates that t his p

Page 45 - Table 7: Modbus commands

Programming ManualPage v March 2014

Page 46 - Register Mappings

Compact Digital Flow Monitor, Model B3000 INTENTIONAL BLANK PAGEPage 50 March 2014

Page 47 - Table 13: Force single coil

Programming ManualINTENTIONAL BLANK PAGEPage 51 March 2014

Page 48 - Page 48 March 2014

www.badgermeter.comBlancett is a registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their res

Page 49

Compact Digital Flow Monitor, Model B3000 Page 6 March 2014INTRODUCTIONThe B3000 flow monitor incorporates state-of-the-art, digital signal processin

Page 50 - INTENTIONAL BLANK PAGE

Programming ManualPage 7 March 2014SPECIFICATIONSDisplayCommonSimultaneously shows Rate and Total5 x 7 Dot Matrix LCD, STN FluidB30A/B/L/M/S6 Digit Ra

Page 51

Compact Digital Flow Monitor, Model B3000 Page 8 March 2014Status Alarms B30B/L/S/W/XNoneModbus Digital CommunicationsB30A/M/Y/ZModbus RTU over RS485

Page 52 - Control. Manage. Optimize

Programming ManualPage 9 March 2014Response Time (Damping)Common Response Time1…100 seconds response to a step change input, user adjustableEnvironmen

Commentaires sur ces manuels

Pas de commentaire